Passive House data coming soon! And new entries on the way.

Utility Data Results
Stream 4.1

Check out the latest information we’ve collected on the real-world performance of high-performance homes in B.C.

The table below shows the latest utility data collected from homes in B.C. that meet one of the following performance criteria: Passive House, Step Code 4 or 5, or CHBA Net Zero.

Applications to the program are still open; new data entries will be added to the table on first Thursday of each month.

Please Note:

  1. Modelled Data Sources: Modelled energy consumption is from the BC Energy Step Code Compliance Report for each house. If the report was unavailable, data was sourced from the EnerGuide Homeowner Information Sheet, Hot2000 modelling, or the Passive House Planning Package.
  2. Actual Data Sources: Actual (real-life) values for energy consumption, GHGI, and energy cost are based on utility bills. Greenhouse Gas Intensity (GHGI) is calculated using electricity and gas consumption, with 2024 emissions factors.
  3. Cooling: All homes have cooling unless indicated otherwise. Although the energy efficiency rating of the house is based on the Energy Step Code Compliance Form or the Passive House Planning Package, the house may not be operating at the modelled energy-efficiency level.
 
Discrepancies between modelled vs. actual energy use:
 
  • Occupants: The model assumes 2.5 people; reality can be 1-7 or more.
  • Climate: The model is based on historical averages; our current weather patterns can differ significantly. For example, the heat dome of 2021 and other outlier events.
  • Energy use: The model provides energy use data for heating, cooling, and ventilating the home and generating hot water; utility data includes all energy use in and around the home. In addition to those modelled, loads reflected in utility bills will also include plug loads and, as applicable: EV charging, hot tubs, saunas, decorative fireplaces, BBQs, etc.
  • Occupant behaviour and equipment set points can have a sizeable impact on energy use that goes beyond what is modelled. For example:
    • extended duration and higher temperature of showers
    • indoor temperature set points; very high (winter) or very low (summer)
    • open windows when the heating/cooling system is in operation
    • equipment set points
    • sizeable plug or vampire loads
    • inefficient lighting

Passive House data coming soon! And new entries on the way.
If you want to share feedback, comments or suggested edits to this table, feel free to email nearzero@zeic.ca

Table 4.1

HouseClimate ZoneGFA sqmAvg # occupantsUtility data collection periodModelled Energy Consumption As-Built (GJ/yr)Actual Energy Consumption (GJ/yr)Actual GHGi (kgCO2e/m2/yr)Energy CostEnergy Cost Total/sq.m/yrSolar Panels (kW)Heating EquipmentVentilation HRV/ERVDHW Equipment Elec/HP/GasNotes
ElectricityFossil FuelElectricityFossil FuelElectricityFossil Fuel
ENERGY STEP CODE 414911Nov 2023-2457.749.71.63$1,202.34$13.24N/AAAHPYesElecEV charging = 17.95GJ
743097Jan 2024-25422043.069.111.58$1,472.68$1,222.40$8.72N/AAAHP, FNoGasAAHP cut off temp 5C
942934Apr 2024-2544.910.641.7100.515.82$1,800.99$1,600.57$11.61N/AAAHP, IFRHNoGasCondensing gas boiler for DHW and space heating (radiant floor in basement)
1441922Jan 2024-25371561.616.56.12$(3,993.40)$686.68$(17.22)24AWHP, IFRHYesGasIn-floor radiant heating, propane boiler for DHW and back-up heating, hot tub, outdoor electric sauna, gas fireplace
262424Nov 2023-24442350.1101.120.31$1,613.18$1,588.69$13.23N/AF, AAHP, IFRHYesGasMain floor gas furnace + AAHP; basement in-floor radiant (hydronic gas); gas fireplace
Average45.117.249.271.811.1
Average without solar$1,522.30$1,470.55$11.70
Average with solar$(3,993.40)$686.68$(17.22)
Average GHGI without gas1.6
Average GHGI with gas13.5
ENERGY STEP CODE 51343134Jun 2024-2562.046.70.38$1,697.20$5.42N/AAAHP, EBYesElecAAHP (ducted)
1743285Jun 2024-2562.0111.61.04$4,090.97$12.47N/AAAHP, EB, ILDHYesElecAAHP for main residence, electric baseboards for suite (no cooling), in-line duct heater for HRV, hot tub
165922Jan 2024-254429.820.91$93.14$1.0115AAHP, ILDHYesElecAAHP (ducted), 5kW in-line duct heater
1252395Jan 2024-255579.11.01$2,514.13$10.52N/AAAHP, EBYesElecMinotair Pentacare V12. Back up electric base boards. Sauna
852984Jun 2023-245485.20.87$3,106.38$10.42N/AAAHP, EBYesHP/ElecMain: AAHP + heat pump DHW; Suite: electric baseboard + DHW
662404Dec 2022-234082.61.05$(1,595.83)$(6.64)12EBYesElecElectric baseboards and electric fan heaters
46982April 2023-2446.5–*50.624.3114.45$1,987.74$830.47$28.76N/AAAHP, EBYesElecDecorative propane fireplace
57B2682May 2023-2446.151.60.59$1,740.00$6.49N/AAAHPYesHP
Average51.267.124.32.5
Average without solar$2,522.74$830.47$12.35
Average with solar$(751.35)$(2.81)
Average GHGI without gas0.8
Average GHGI with gas14.5

Acronyms
AAHP = air to air heat pump
AWHP = air to water heat pump
EB = electric baseboards
F= furnace, gas
IFRH = in-floor radiant heating
ILDH = in line duct heater
DHW = domestic hot water
EV = electric vehicle
Elec = electric
HP = heat pump

Project brought to you by: